Standard Range
| Model |
SCUV™ 400 |
SCUV™ 800 |
SCUV™ 1200 |
SCUV™ 1600 |
SCUV™ 2000 |
SCUV™ 2400 |
SCUV™ 3200 |
SCUV™ 4000 |
| No. of SCUV™ Treatment Modules |
1 |
2 |
3 |
4 |
5 |
6 |
8 |
10 |
| Max Flow Rate Capacity m³/day* |
570 |
1140 |
1700 |
2280 |
2880 |
3420 |
4560 |
5700 |
| Max Flow Rate Capacity m³/hr* |
24 |
48 |
72 |
96 |
120 |
144 |
192 |
240 |
| Max Flow Rate Capacity l/s* |
6.7 |
13.3 |
20.0 |
26.7 |
33.3 |
40.0 |
53.3 |
66.7 |
| Max Flow Rate Capacity US gal/min* |
106 |
211 |
317 |
423 |
529 |
634 |
845 |
1057 |
* Note: Maximum flow rate differs for each application and lower throughput rates are required for very difficult-to-treat liquids.
Lamps & Lamp Monitoring
| Model |
SCUV™ 400 |
SCUV™ 800 |
SCUV™ 1200 |
SCUV™ 1600 |
SCUV™ 2000 |
SCUV™ 2400 |
SCUV™ 3200 |
SCUV™ 4000 |
| Number of Ultraviolet Lamps |
2 |
4 |
6 |
8 |
10 |
12 |
16 |
20 |
| Max. Lamp Power (Combined) W. |
520 |
1040 |
1560 |
2080 |
2600 |
3120 |
4160 |
5200 |
| Ultraviolet Lamp |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
| Energy Consumption (J/L) at max. flow rate. |
78 |
78 |
78 |
78 |
78 |
78 |
78 |
78 |
Standard Features & Inclusions
| Model |
SCUV™ 400 |
SCUV™ 800 |
SCUV™ 1200 |
SCUV™ 1600 |
SCUV™ 2000 |
SCUV™ 2400 |
SCUV™ 3200 |
SCUV™ 4000 |
| Individual Lamp Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp Temperature Control |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Parallel Processing |
Optional |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Automatic Flowrate Management |
Optional |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| UVI Sensor |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Automated Flush System |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
| Automated Lamp-Out Alarm |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Automated Lamp-Out Module Switch-Over |
Optional |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Valve & Flow Meter Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp Life-Time Hours |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp/status Indicator LED |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Safety Cut Out Switch |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Stainless Steel Inlets and Outlet |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| User Interface Touch Screen |
Optional |
Optional |
Optional |
Optional |
Yes |
Yes |
Yes |
Yes |
| Control System |
Embedded PC |
Embedded PC |
Embedded PC |
Embedded PC |
PLC |
PLC |
PLC |
PLC |
| 4G SIM Remote Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Continuous Monitoring Camera |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Containerised Housing |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Air Conditioning Unit |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
Operating Requirements
| Model |
SCUV™ 400 |
SCUV™ 800 |
SCUV™ 1200 |
SCUV™ 1600 |
SCUV™ 2000 |
SCUV™ 2400 |
SCUV™ 3200 |
SCUV™ 4000 |
| Power Supply Requirements |
1-PH, 10A |
1-PH, 10A |
3-PH, 16A |
3-PH, 16A |
3-PH, 20A |
3-PH, 20A |
3-PH, 32A |
3-PH, 32A |
| Power Allowance for Air-Conditioning |
Excluded |
Excluded |
Excluded |
Excluded |
Included |
Included |
Included |
Included |
| Max. Operating Pressure (Bar) |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
| Min. Operating Pressure (Bar) |
0.5 Bar |
0.5 Bar |
0.5 Bar |
1 Bar |
1 Bar |
1 Bar |
1 Bar |
1 Bar |
| Max. Particulate Size (micron)* |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
| pH Range |
** |
** |
** |
** |
** |
** |
** |
** |
| Max. Liquid Viscosity |
*** |
*** |
*** |
*** |
*** |
*** |
*** |
*** |
Plus Range
| Model |
SCUV™ 400 Plus |
SCUV™ 800 Plus |
SCUV™ 1200 Plus |
SCUV™ 1600 Plus |
SCUV™ 2000 Plus |
SCUV™ 2400 Plus |
SCUV™ 3200 Plus |
SCUV™ 4000 Plus |
| No. of SCUV™ Treatment Modules |
1 |
2 |
3 |
4 |
5 |
6 |
8 |
10 |
| Max Flow Rate Capacity m³/day* |
570 |
1140 |
1700 |
2280 |
2880 |
3420 |
4600 |
5700 |
| Max Flow Rate Capacity m³/hr* |
24 |
48 |
72 |
96 |
120 |
144 |
192 |
240 |
| Max Flow Rate Capacity l/s* |
6.7 |
13.3 |
20.0 |
26.7 |
33.3 |
40.0 |
53.3 |
66.7 |
| Max Flow Rate Capacity US gal/min* |
106 |
211 |
317 |
423 |
529 |
634 |
845 |
1057 |
* Note: Maximum flow rate differs for each application and lower throughput rates are required for very difficult-to-treat liquids.
Lamps & Lamp Monitoring
| Model |
SCUV™ 400 Plus |
SCUV™ 800 Plus |
SCUV™ 1200 Plus |
SCUV™ 1600 Plus |
SCUV™ 2000 Plus |
SCUV™ 2400 Plus |
SCUV™ 3200 Plus |
SCUV™ 4000 Plus |
| Number of Ultraviolet Lamps |
4 |
8 |
12 |
16 |
20 |
24 |
32 |
40 |
| Max. Lamp Power (Combined) W. |
1040 |
2080 |
3120 |
4160 |
5200 |
6240 |
8320 |
10400 |
| Ultraviolet Lamp |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
High Output, Low-pressure Amalgam |
| Energy Consumption (J/L) at Max. Flow Rate. |
156 |
156 |
156 |
156 |
156 |
156 |
156 |
156 |
Standard Features & Inclusions
| Model |
SCUV™ 400 Plus |
SCUV™ 800 Plus |
SCUV™ 1200 Plus |
SCUV™ 1600 Plus |
SCUV™ 2000 Plus |
SCUV™ 2400 Plus |
SCUV™ 3200 Plus |
SCUV™ 4000 Plus |
| Individual Lamp Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp Temperature Control |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Parallel Processing |
Optional |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Automatic Flowrate Management |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| UVI Sensor |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Automated Flush System |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
Recommended |
| Automated Lamp-Out Alarm |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Automated Lamp-Out Module Switch-Over |
Optional |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Valve & Flow Meter Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp Life-Time Hours |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp/status Indicator LED |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Safety Cut Out Switch |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Stainless Steel Inlets and Outlet |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| User Interface Touch Screen |
Optional |
Optional |
Optional |
Optional |
Yes |
Yes |
Yes |
Yes |
| Control System |
Embedded PC |
Embedded PC |
Embedded PC |
Embedded PC |
PLC |
PLC |
PLC |
PLC |
| 4G SIM Remote Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Continuous Monitoring Camera |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Containerised Housing |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| Air Conditioning Unit |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
As Required |
Operating Requirements
| Model |
SCUV™ 400 Plus |
SCUV™ 800 Plus |
SCUV™ 1200 Plus |
SCUV™ 1600 Plus |
SCUV™ 2000 Plus |
SCUV™ 2400 Plus |
SCUV™ 3200 Plus |
SCUV™ 4000 Plus |
| Power Supply Requirements |
1-PH, 10A |
1-PH, 16A |
3-PH, 20A |
3-PH, 20A |
3-PH, 32A |
3-PH, 32A |
3-PH, 32A |
3-PH, 32A |
| Power Allowance for Air-Conditioning |
Excluded |
Excluded |
Excluded |
Excluded |
Included |
Included |
Included |
Included |
| Max. Operating Pressure (Bar) |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
7.5 Bar |
| Min. Operating Pressure (Bar) |
0.5 Bar |
0.5 Bar |
0.5 Bar |
1 Bar |
1 Bar |
1 Bar |
1 Bar |
1 Bar |
| Max. Particulate Size (micron)* |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
| pH Range |
** |
** |
** |
** |
** |
** |
** |
** |
| Max. Liquid Viscosity |
*** |
*** |
*** |
*** |
*** |
*** |
*** |
*** |
* larger particle throughput possible on request (Subject to treatment goals).
** Contact NovoLabs™ to discuss liquids that are not neutral
*** Contact NovoLabs™ to discuss any highly viscous liquids requiring treatment