Technical Data & System Specifications

NovoLabs™ Modular SCUV Series — for Low UVT applications

The NovoLabs™ SCUV novel technology has patents granted, or pending in the USA, Canada, China, Europe, India, Australia and New Zealand. New Zealand Patent Application Nos. 741319 and 783308.

Modular SCUV Series
Model SCUV 400 SCUV 400 Plus SCUV 800 SCUV 800 Plus SCUV 1600 SCUV 1600 Plus SCUV 2400 SCUV 2400 Plus SCUV 3200 SCUV 3200 Plus SCUV 4000 SCUV 4000 Plus
No. of SCUV Treatment Modules 1 1 2 2 4 4 6 6 8 8 10 10
Max Flow Rate Capacity m³/day* 570 570 1140 1140 2280 2280 3420 3420 4560 4560 5700 5700
Max Flow Rate Capacity L/min* 400 400 800 800 1600 1600 2400 2400 3200 3200 4000 4000
Max Flow Rate Capacity L/s* 6.7 6.7 13.3 13.3 26.7 26.7 40.0 40.0 53.3 53.3 66.7 66.7

* Note: Maximum flow rate differs for each application and is subject to site-specific testing. Lower throughput rates are required for very low UVT difficult-to-treat liquids.

Lamps & Lamp Monitoring
Model SCUV 400 SCUV 400 Plus SCUV 800 SCUV 800 Plus SCUV 1600 SCUV 1600 Plus SCUV 2400 SCUV 2400 Plus SCUV 3200 SCUV 3200 Plus SCUV 4000 SCUV 4000 Plus
Number of UV Lamps 2 4 4 8 8 16 12 24 16 32 20 40
Max. Lamp Power (Combined) W. 520 1040 1040 2080 2080 4160 3120 6240 4160 8320 5200 10400
UV Lamp High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam High Output, Low-pressure Amalgam
Energy Consumption (J/L) at max. flow rate. 78 156 78 156 78 156 78 156 78 156 78 156
Standard Features & Inclusions
Model SCUV 400 SCUV 400 Plus SCUV 800 SCUV 800 Plus SCUV 1600 SCUV 1600 Plus SCUV 2400 SCUV 2400 Plus SCUV 3200 SCUV 3200 Plus SCUV 4000 SCUV 4000 Plus
Individual Lamp Monitoring Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Lamp Temperature Control Optional Yes Optional Yes Optional Yes Optional Yes Optional Yes Optional Yes
Parallel Processing No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Automatic Flowrate Management Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Automated Flush System Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Automated Lamp-Out Alarm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Automated Lamp-Out Module Switch-Over No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Low Flow Alert Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Return Flow Monitoring No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Valve & Flow Meter Monitoring Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Lamp Life-Time Hours Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
UV-safe lamp check sightglasses Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Multiple cut out switches (Safety) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Stainless Steel inlet and outlet Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Air Conditioning Unit As Required As Required As Required As Required As Required As Required As Required As Required As Required As Required As Required As Required
Inflow Blockage Prevention Screen Required Required Required Required Required Required Required Required Required Required Required Required
Second Standby Inflow Screen for Continuous Operation Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional
Inlet Screen
Back-pressure Monitoring & Alert
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Monitor Micro Micro PLC PLC PLC PLC PLC PLC PLC PLC PLC PLC
4G SIM Remote Monitoring Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Continuous Monitoring Camera Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Operating Requirements
Model SCUV 400 SCUV 400 Plus SCUV 800 SCUV 800 Plus SCUV 1600 SCUV 1600 Plus SCUV 2400 SCUV 2400 Plus SCUV 3200 SCUV 3200 Plus SCUV 4000 SCUV 4000 Plus
Power Supply Requirements 1-PH, 10A 1-PH, 10A 1-PH, 10A 1-PH, 16A 3-PH, 16A 3-PH, 20A 3-PH, 20A 3-PH, 32A 3-PH, 32A 3-PH, 32A 3-PH, 32A 3-PH, 32A
Power allowance for air-conditioning Excluded Excluded Excluded Excluded Included Included Included Included Included Included Included Included
Max. Operating Pressure (Bar) 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar 7.5 Bar
Min. Operating Pressure (Bar) 0.5 Bar 0.5 Bar 0.5 Bar 0.5 Bar 1 Bar 1 Bar 1 Bar 1 Bar 1 Bar 1 Bar 1 Bar 1 Bar
Max. Particulate Size (micron)* 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
pH Range ** ** ** ** ** ** ** ** ** ** ** **
Max. Liquid Viscosity *** *** *** *** *** *** *** *** *** *** *** ***

* larger particle throughput possible on request (Subject to treatment goals).
** Contact NovoLabs™ to discuss liquids that are not neutral
*** Contact NovoLabs™ to discuss any highly viscous liquids requiring treatment

A PDF version of our Specifications are available as a download here. Click on the Icon

Peace of Mind

NovoLabs™ smart system continually monitors flow rates and system status and will auto-divert flow to another module in the event of a lamp outage — ensuring performance protection day and night.

Health & Safety

NovoLabs™ modules are mounted on a pull-out slider system with a flip-up lid making access for inspection or lamp-change quick, clean, safe and effortless. No messy disconnections are required.

Optimising Efficiency

The NovoLabs™ system constantly monitors and actively manages lamp temperature to ensure that they are always operating in the optimal temperature window for UV-C light output.

User Friendly

Intuitive, easy-to-use PLC Interface and flow meter array makes operating and monitoring straight-forward.

Discover The Future of UV Disinfection

Novolabs™ Supercritical UV™ Disinfection — UV Treatment for Low Clarity Liquids